These cables are built specifically for use underwater and used in our products! A polyurethane jacket and flexible conductors make for a rugged cable. Sold by the meter (3.3 ft) and cut to length when you order.

These cables are built for a wide range of subsea applications, custom made with a pressure-extruded polyurethane jacket and flexible conductors. They are very tough and abrasion resistant.

Ping Cable ( 4 Conductors, 24 AWG):

This 4-conductor cable is used on the Ping Echosounder. The cable is made with a pressure-extruded polyurethane jacket and flexible 24 AWG conductors. It’s compatible with the WLP-M06-4.5MM-LC and WLP-M10-4.5MM-LC WetLink Penetrator.

Ethernet and Power Cable (2 x 22 AWG, 4 x UTP 26 AWG):

This cable has separate wires for Ethernet and power transmission, making it a useful cable for many different types of underwater connections! Ethernet is unshielded 26 AWG twisted pairs and the power is thicker 22 AWG to handle higher current applications. It’s compatible with the WLP-M10-7.5MM-LC WetLink Penetrator.

Lumen/Gripper Cable (3 Conductors, 22 AWG):

This 3-conductor cable is used on the Lumen Subsea Lights and the Newton Gripper. A polyurethane jacket and polypropylene-insulated 22 AWG conductors make for a rugged cable. It’s compatible with the WLP-M06-4.5MM-LC and WLP-M10-4.5MM-LC WetLink Penetrator.

These cables are used in the the Newton Gripper, the Ping Echosounder, the Lumen Lights, and in countless other applications!

Contents

Specifications

Cable Lumen/Gripper Cable Ping Cable Ethernet and Power Cable
Construction 3-conductors, jacket 4-conductors, powder separator, jacket 2-conductor 22 AWG, 4-unshielded twisted pairs 26 AWG, filler, wrap, jacket
Diameter 4.5 mm 4.5 mm 7.5 mm
Outer Jacket Pressure-extruded polyurethane Pressure-extruded polyurethane Pressure-extruded polyurethane
Wrap - - 2-layer non-woven wrap
Filler - - String
Number of Conductors 3 4 2 x 22 AWG
8 x 26 AWG
Conductor Gauge 22 AWG 24 AWG 22 AWG
26 AWG (UTP)
Conductor Insulation Polypropylene Polypropylene Polypropylene (22 AWG)
FEP (UTP)
Conductor Insulation Colors Black, red, yellow Black, white, green, red Black
Red
Blue, blue/white
Brown, brown/white
Green, green/white
Orange, orange/white
Static Minimum Bend Radius 15 mm 15 mm 24 mm
Compatible WetLink Penetrator M06-4.5mm-LC
M10-4.5mm-LC
M06-4.5mm-LC
M10-4.5mm-LC
M10-7.5mm-LC
BlueRobotics
Add-ons
PUR Subsea Cable
PUR Subsea Cable
PUR Subsea Cable
PUR Subsea Cable
  • SKU: BR-101050

PUR Subsea Cable

$24.00

    These cables are built specifically for use underwater and used in our products! A polyurethane jacket and flexible conductors make for a rugged cable. Sold by the meter (3.3 ft) and cut to length when you order.

    These cables are built for a wide range of subsea applications, custom made with a pressure-extruded polyurethane jacket and flexible conductors. They are very tough and abrasion resistant.

    Ping Cable ( 4 Conductors, 24 AWG):

    This 4-conductor cable is used on the Ping Echosounder. The cable is made with a pressure-extruded polyurethane jacket and flexible 24 AWG conductors. It’s compatible with the WLP-M06-4.5MM-LC and WLP-M10-4.5MM-LC WetLink Penetrator.

    Ethernet and Power Cable (2 x 22 AWG, 4 x UTP 26 AWG):

    This cable has separate wires for Ethernet and power transmission, making it a useful cable for many different types of underwater connections! Ethernet is unshielded 26 AWG twisted pairs and the power is thicker 22 AWG to handle higher current applications. It’s compatible with the WLP-M10-7.5MM-LC WetLink Penetrator.

    Lumen/Gripper Cable (3 Conductors, 22 AWG):

    This 3-conductor cable is used on the Lumen Subsea Lights and the Newton Gripper. A polyurethane jacket and polypropylene-insulated 22 AWG conductors make for a rugged cable. It’s compatible with the WLP-M06-4.5MM-LC and WLP-M10-4.5MM-LC WetLink Penetrator.

    These cables are used in the the Newton Gripper, the Ping Echosounder, the Lumen Lights, and in countless other applications!

    Contents

    • 1x Selected cable with bare ends, cut to length

    Specifications

    Cable Lumen/Gripper Cable Ping Cable Ethernet and Power Cable
    Construction 3-conductors, jacket 4-conductors, powder separator, jacket 2-conductor 22 AWG, 4-unshielded twisted pairs 26 AWG, filler, wrap, jacket
    Diameter 4.5 mm 4.5 mm 7.5 mm
    Outer Jacket Pressure-extruded polyurethane Pressure-extruded polyurethane Pressure-extruded polyurethane
    Wrap - - 2-layer non-woven wrap
    Filler - - String
    Number of Conductors 3 4 2 x 22 AWG
    8 x 26 AWG
    Conductor Gauge 22 AWG 24 AWG 22 AWG
    26 AWG (UTP)
    Conductor Insulation Polypropylene Polypropylene Polypropylene (22 AWG)
    FEP (UTP)
    Conductor Insulation Colors Black, red, yellow Black, white, green, red Black
    Red
    Blue, blue/white
    Brown, brown/white
    Green, green/white
    Orange, orange/white
    Static Minimum Bend Radius 15 mm 15 mm 24 mm
    Compatible WetLink Penetrator M06-4.5mm-LC
    M10-4.5mm-LC
    M06-4.5mm-LC
    M10-4.5mm-LC
    M10-7.5mm-LC
    BACK TO TOP